2699 TRAP PRIMERS AND FITTINGS

 

 

 

2699 Automatic Trap Primer

 

 

 
2695/2696/2697 2698
AUTOMATIC TRAP PRIMER
FUNCTION: Used where trapped drains are installed in locations used infrequently or other conditions might permit water seal to evaporate, allowing sewer gas or objectionable and contaminating odors to escape through drain. A trap primer is recommended to compensate for evaporation and insure maintenance of a water seal in trap at all times.
Regularly Furnished: Optional Materials:
Cast Bronze with 1/2" Connection as Indicated by Figure Number Selected. Satin Finish Chrome Plated  -CP

2699 Automatic Trap Primer

Fig. 2699.......1/2" NPT FEMALE

Fig. 2699-1.......1/2" COPPER SWEAT

APPLICATION, INSTALLATION AND OPERATING PRINCIPLE
The Smith Trap Seal Primer Valve, when properly installed in a cold water supply line running to a frequently used fixture and connected to a floor drain trap, will insure a constant seal of fresh water in the drain trap.
When water is drawn at the plumbing fixture the resulting flow activates the trap primer valve mechanism. A precise amount of water is dispensed into the trap at the beginning and end of flow in the fixture supply line.
Air ports in the primer body prevent siphonage of trap water into the water supply line. If the trap water seal is not constantly maintained, the water will evaporate from the trap, allowing sewer gas to escape into the building from the sewer lines.