Manufacturers have slight
differences in the depth of the closet horn and flange thickness of their
closets. Usually the fixture support closet connection should extend 5/16”
beyond face of finished wall (Dimension “R”) and the fixture
studs 2 1/4” (dimension “X”). For exact dimensions,
please use the formulas below:
DETAIL A
S + 1/16” - D = R
- R =
Distance coupling should extend beyond finished wall.
- S =
Depth closet horn
- 1/16”
= Distance closet is to set away from finished wall.
- *D
= 1/2” for felt gasket and 3/8” for neoprene gasket.
- NOTE:
- When
the fixture is installed, closet gasket must be compressed sufficiently
to assure a gas and water tight seal.
- DETAIL
B Y
+ 1/16” + 9/16” = X
- X = Distance
supporting stud should extend beyond finished wall.
- Y = Thickness
of closet wall flange.
- 1/16” = Distance
closet is to set away from finished wall.
- NOTE:
- Bearing nuts
and washers must be set to take full loading from the fixture.
|
 |