| The overflow device is connected to the overflow pipe within the storage container. The device can prevent the entry of drain odors
from the storm drain into the storage container, provides backflow protection, and removes surface debris through a skimming effect. |

Fig. Number: RH9530DOK – Multi-functional Overflow Device
Function: The Multi-functional overflow device is made of impact-resistant
| ABS
plastic that eliminates drain odors in the storage tank, provides vermin and
backflow protection, and skims surface debris. Comes with support strut, clamp,
and fits 4 inch overflow piping. Resources:
Submittal (pdf)
Drawing (dwg) |
 |
|
| SENSOR TYPE STORAGE TANK LEVEL INDICATOR |
| Sensor level indicator shows the water level in the storage
tank using a wireless device. This device transmits an ultrasonic sound wave that echoes back from the fluid surface. That echo is converted to a depth and displayed on the indoor bench unit indicating the depth of the water in the storage tank. |
 |
Fig. Number: RH9530LI
Function: Wireless sensor that gives remote tank level readings. Sensor has an operating range of up to
1,640 feet. The maximum detection range is 13 feet. Sensor and bench unit operate on four “AA” batteries. |
|
| PURIFICATION KIT (Optional Component for Packages 4, 5, 6 and 7) |
| Designed to treat rainwater for potable uses. |
 |
RH9550PK – Purification Kit (Optional Component for Packages 4, 5, 6 and 7) To purchase, the Purification Kit must be approved by a licensed plumbing engineer.
Function: Treats rainwater for potable uses. Kit includes 20”
filter housing (2), 1 string wound micron sediment filter, carbon filter for odor and taste, mounting brackets (2), filter wrench (2), and 15 g.p.m. ultraviolet light. |
| To control water level or feed. |

Specify Suction/Booster Pump Voltage:
115 Volts – Figure Number: RH9540-1BP115
220 Volts – Figure Number: RH9540-1BP220
| 1 Horsepower Suction/Booster Pump
(Specify 115 or 220 volts, single phase) –
Figure Number: RH9540-1BP, a complete unit includes a pump, motor, diaphragm
tank, pressure and flow sensor, control and check valve for residential applications.
The controller ensures that the pump starts automatically when water is consumed
and stops automatically when the consumption ceases.
Operating specification for booster pump
(RH9540-1BP):
System Pressure – Max. 109 psi (7.5 bar)
Inlet Pressure – Max. 44 psi (3 bar)
Suction Lift – Max. 26 ft.
Liquid Temperature – 32ºF to 95 ºF
Ambient Temperature – 32ºF to 113 ºF
|
| To control water level or feed. |

| RH9542FSO – Dry Run Protection, Normally Open (N/O)
Function: To turn off pump at low water level. Float switch to be fixed
on the inlet pipe or submersible pump. The float switch starts the pump at minimum level in the storage container or cistern. Float switch comes
with switch level and float housing of polyethylene with flexible cable. (Switch level is defined as the exact switch points where the water does
not go below set level of 1.5 inches).
|
| RH9542FSC –
Back-up Water Feed, Normally Closed (N/C)
Function: To control normally closed solenoid valve for second source water feed. Float switch to be fixed on the inlet pipe or submersible pump. Float
switch comes with switch level and float housing of polyethylene with flexible cable. (Switch level is defined as the exact switch point where the water level rises to desired level).
|
|